Download 5995668042 Electrolux Technical Service Manual Dishwasher 2015 PDF

Title5995668042 Electrolux Technical Service Manual Dishwasher 2015
File Size3.5 MB
Total Pages30
Document Text Contents
Page 1

Publication #5995668042 December 2015

Technical Service Manual
DISHWASHERS

Page 15

15

“i92” – code: checksum CCF
• The error is signalled if the configuration control of

the washing cycles provided erroneous results.

“i93” – code: checksum UIDATA
• The error is signalled if the configuration control

of the UI configuration data provided erroneous
results.

“i94” – code: UIDATA version
mismatch
• The error is signalled if the UIDATA provided in

configuration file mismatches the attached UI
board.

“i95” – code: UIDATA checksum
mismatch
• The error is signalled if the UIDATA checksum type

provided in configuration file mismatches with the
attached UI board.

“iB0” Code - family : Sensor
Problem

“iB0” - code: turbidity sensor
• The error is set if the calibration procedure is not

completed after 15 sec.

• The washing program will run as though the dirt
value to be considered is high

“iC0” Code - family:
Communication Problem

“iC0” – code: user interface
communication
• The error signal is displayed if the communication

system does not recognize any display board.

“iC1” – code: MACS bus
communication
• After three attempts to establish communication,

an error is signalled in the hardware control

“iC2” – Code: ADSI communication
• The washing programme is suspended but it can

be restarted if the error conditions no longer
apply

“iC3” – Code: Communication
between the power board and the
Motor Control Board
• The error is signalled if the communication

between the Motherboard and the Motor Control
Board does not start.

• Acoustic signal and visual error, depending on the
appliance customization; the washing program is
restarted automatically if the error conditions no
longer apply.

“iD0” Code - family: Tacho
Problem

“iD0” – code: no signal
• The error is stored and displayed only in service

mode; there is a new control for each new phase.

• If the washing pump is activated but there is no
tacho signal for 30 seconds then the motor speed
is set to full speed and the heating element is not
activated.

“iD1” – code: critical signal
• The error is stored and displayed only in service

mode.

• If the washing pump is activated but there is
no tacho signal for 5 seconds then the heating
element is temporarily deactivated. If after
another 30 seconds there is still no signal the
appliance displays an error code iD0.

Page 16

16

“iE0” – family: flow controller problem

“iE0” – code: flow control position (spray arm level)
• The error is stored and displayed only in service mode; there is a new control for each new phase.

• The error is signalled if the desired position of the flow controller is not reached after 120 seconds; the
heating element is deactivated.

• If the signal from the flow controller does not change after 15 seconds, the software suspends the
positioning for 2 seconds and resumes after another max 120 seconds.

“iF0” Code - family: water level problem

“iF0” – Code: overfilling detected
• The error is stored and displayed only in service mode; the program continues.

• The error situation is recognized when the total filling times exceed the limits.

• The times are accumulated at each subsequent filling and reset every time the drain is activated.

• If the error is detected, the heating element is not activated and the subsequent fillings are ignored.

“iF1” – code: high water level
• The error is stored and displayed only in service mode.

• The error condition is recognized if the safety water level is exceeded for more than 4 seconds.

• A drain phase is activated until the water level drops below the safety level.

• The washing program continues only if this condition is achieved

SERVICE
ERROR
CODE

REASON
UNIT REPSONSE

INDICATION DURING
FAILURE

CHECK WHEN FAILURE APPEARS.

i00
PCB Failure
UI or PCB
Loose Connection

User interface will be
OFF.

1. Check main power supply
2. Check UI and PCB connections

i10
A low fill has been
detected.

Cycle will pause
requiring user to
restart.

1. Water tap or Main water supply OFF?
2. Electrical connection of water valve.
3. Blocked water or pinched water supply line.

i20
Slow or no drain
problem.

Cycle will pause
requiring user to
restart.

1. Check and ensure filter is clean.
2. Check for buildup of soils in sump.
3. Ensure check vavle is functioning properly.
4. Make sure that the drain pump is not blocked
and operating normally.
5. Check drain hose Installation and for any
obstructions.
6. Check for a pinched or blocked drain hose.
7. Check that the knockout plug on the disposer
was removed during installation.

4.4 List of Error Codes

Page 29

29

5.18 Control Board for PB100/PB200

5.19 Control Board Replacement

Page 30

30

5.20 Example Wiring Diagram for PB100

5.21 Example Wiring Diagram for PB200